type: position_score table: filename: ENCFF784YVX.tabix.bed.gz header_mode: none zero_based: true format: tabix chrom: column_index: 0 pos_begin: column_index: 1 pos_end: column_index: 2 scores: - id: TF_ChIP-seq_ENCSR680OFU column_index: 3 type: float desc: 'TF_ChIP-seq ENCSR680OFU [biosample_summary="Homo sapiens HeLa-S3" and target="EP300"]' histogram: type: number number_of_bins: 100 meta: summary: 'TF_ChIP-seq ENCSR680OFU [biosample_summary="Homo sapiens HeLa-S3" and target="EP300"]' description: "**status**: released\n\n**biological\\_replicates**: Rep 1, Rep 2\n\ \n**summary**: \n\n**output\\_type**: optimal IDR thresholded peaks\n\n**audit\\\ _internal\\_action**: Archived analysis {ENCAN443OCA|/analyses/ENCAN443OCA/} has\ \ in progress subobject quality standard {encode3-tf-chip|/quality-standards/encode3-tf-chip/}\n\ \n**audit\\_warning**: Processed alignments file {ENCFF952XCP|/files/ENCFF952XCP/}\ \ processed by ChIP-seq ENCODE3 hg19 pipeline has 17891090 usable fragments. The\ \ minimum ENCODE standard for each replicate in a ChIP-seq experiment targeting\ \ EP300-human and investigated as a transcription factor is 10 million usable\ \ fragments. The recommended value is > 20 million, but > 10 million is acceptable.\ \ (See {ENCODE ChIP-seq data standards|/data-standards/chip-seq/} )\n\n**audit\\\ _warning**: Replicate concordance in ChIP-seq experiments is measured by calculating\ \ IDR values (Irreproducible Discovery Rate). ENCODE processed IDR thresholded\ \ peaks files {ENCFF583XDA|/files/ENCFF583XDA/}, {ENCFF784YVX|/files/ENCFF784YVX/}\ \ processed by ChIP-seq ENCODE3 hg19 pipeline have a rescue ratio of 1.67 and\ \ a self consistency ratio of 2.72. According to ENCODE standards, having both\ \ rescue ratio and self consistency ratio values < 2 is recommended, but having\ \ only one of the ratio values < 2 is acceptable.\n\n**audit\\_warning**: Replicate\ \ concordance in ChIP-seq experiments is measured by calculating IDR values (Irreproducible\ \ Discovery Rate). ENCODE processed IDR thresholded peaks files {ENCFF240IVA|/files/ENCFF240IVA/},\ \ {ENCFF803UTK|/files/ENCFF803UTK/} processed by ChIP-seq ENCODE3 hg19 pipeline\ \ have a rescue ratio of 1.67 and a self consistency ratio of 2.72. According\ \ to ENCODE standards, having both rescue ratio and self consistency ratio values\ \ < 2 is recommended, but having only one of the ratio values < 2 is acceptable." labels: reference_genome: hg38/genomes/GRCh38-hg38 accession: ENCSR680OFU status: released assay_term_name: ChIP-seq simple_biosample_summary: '' biosample_summary: Homo sapiens HeLa-S3 replication_type: isogenic biosample_ontology: /biosample-types/cell_line_EFO_0002791/ perturbed: false doi: 10.17989/ENCSR680OFU date_created: '2014-07-02T22:44:17.707488+00:00' date_released: '2014-07-07' submitter_comment: As of March 5th, 2018, the Antibody Review Board has exempted this antibody, therefore releasing this experiment. target: EP300