type: position_score table: filename: ENCFF992KBL.tabix.bed.gz header_mode: none zero_based: true format: tabix chrom: column_index: 0 pos_begin: column_index: 1 pos_end: column_index: 2 scores: - id: TF_ChIP-seq_ENCSR228PGT column_index: 3 type: float desc: signal histogram: type: number number_of_bins: 100 meta: summary: 'ChIP-seq ENCSR228PGT [TISSUE: Homo sapiens HEK293 genetically modified (insertion) using site-specific recombination targeting H. sapiens ZNF292, TARGET: ZNF292]' description: '**status**: released **biological\_replicates**: Rep 1, Rep 2 **summary**: genetically modified (insertion) using site-specific recombination targeting H. sapiens ZNF292 **output\_type**: IDR thresholded peaks **audit\_internal\_action**: Released analysis {ENCAN964UFJ|/analyses/ENCAN964UFJ/} has in progress subobject quality standard {encode4-tf-chip|/quality-standards/encode4-tf-chip/} **audit\_internal\_action**: Released analysis {ENCAN964UFJ|/analyses/ENCAN964UFJ/} has in progress subobject document {7066834a-f71f-4bd7-807f-6412d17ce8b9|/documents/7066834a-f71f-4bd7-807f-6412d17ce8b9/} **audit\_warning**: Processed alignments file {ENCFF602MXY|/files/ENCFF602MXY/} processed by ChIP-seq ENCODE4 v1.5.1 GRCh38 pipeline has 14875772 usable fragments. The minimum ENCODE standard for each replicate in a ChIP-seq experiment targeting ZNF292-human and investigated as a transcription factor is 10 million usable fragments. The recommended value is > 20 million, but > 10 million is acceptable. (See {ENCODE ChIP-seq data standards|/data-standards/chip-seq/} ) **audit\_warning**: Replicate concordance in ChIP-seq experiments is measured by calculating IDR values (Irreproducible Discovery Rate). ENCODE processed IDR thresholded peaks files {ENCFF992KBL|/files/ENCFF992KBL/} processed by ChIP-seq ENCODE4 v1.5.1 GRCh38 pipeline have a rescue ratio of 1.16 and a self consistency ratio of 2.73. According to ENCODE standards, having both rescue ratio and self consistency ratio values < 2 is recommended, but having only one of the ratio values < 2 is acceptable. **audit\_warning**: Replicate concordance in ChIP-seq experiments is measured by calculating IDR values (Irreproducible Discovery Rate). ENCODE processed IDR thresholded peaks files {ENCFF460VUS|/files/ENCFF460VUS/} processed by ChIP-seq ENCODE4 v1.5.1 GRCh38 pipeline have a rescue ratio of 1.16 and a self consistency ratio of 2.73. According to ENCODE standards, having both rescue ratio and self consistency ratio values < 2 is recommended, but having only one of the ratio values < 2 is acceptable.' labels: reference_genome: hg38/genomes/GRCh38-hg38 accession: ENCSR228PGT status: released assay_term_name: ChIP-seq simple_biosample_summary: genetically modified (insertion) using site-specific recombination targeting H. sapiens ZNF292 biosample_summary: Homo sapiens HEK293 genetically modified (insertion) using site-specific recombination targeting H. sapiens ZNF292 replication_type: isogenic biosample_ontology: /biosample-types/cell_line_EFO_0001182/ perturbed: false doi: 10.17989/ENCSR228PGT date_created: '2016-03-29T17:49:45.627369+00:00' date_released: '2016-10-07' submitter_comment: '' target: ZNF292