type: position_score table: filename: ENCFF955LND.tabix.bed.gz header_mode: none zero_based: true format: tabix chrom: column_index: 0 pos_begin: column_index: 1 pos_end: column_index: 2 scores: - id: TF_ChIP-seq_ENCSR076SHT column_index: 3 type: float desc: 'TF_ChIP-seq ENCSR076SHT [biosample_summary="Homo sapiens HepG2 genetically modified (insertion) using CRISPR targeting H. sapiens GPN1" and target="GPN1"]' histogram: type: number number_of_bins: 100 meta: summary: 'TF_ChIP-seq ENCSR076SHT [biosample_summary="Homo sapiens HepG2 genetically modified (insertion) using CRISPR targeting H. sapiens GPN1" and target="GPN1"]' description: '**status**: released **biological\_replicates**: Rep 1, Rep 2 **summary**: genetically modified (insertion) using CRISPR targeting H. sapiens GPN1 **output\_type**: IDR thresholded peaks **audit\_internal\_action**: Released analysis {ENCAN578KRU|/analyses/ENCAN578KRU/} has in progress subobject quality standard {encode4-tf-chip|/quality-standards/encode4-tf-chip/} **audit\_internal\_action**: Released analysis {ENCAN578KRU|/analyses/ENCAN578KRU/} has in progress subobject document {b32d4c51-de0d-483f-bf49-6ac9809ecd1d|/documents/b32d4c51-de0d-483f-bf49-6ac9809ecd1d/} **audit\_warning**: Replicate concordance in ChIP-seq experiments is measured by calculating IDR values (Irreproducible Discovery Rate). ENCODE processed IDR thresholded peaks files {ENCFF955LND|/files/ENCFF955LND/} processed by ChIP-seq ENCODE4 v1.5.1 GRCh38 pipeline have a rescue ratio of 1.34 and a self consistency ratio of 2.86. According to ENCODE standards, having both rescue ratio and self consistency ratio values < 2 is recommended, but having only one of the ratio values < 2 is acceptable. **audit\_warning**: Replicate concordance in ChIP-seq experiments is measured by calculating IDR values (Irreproducible Discovery Rate). ENCODE processed IDR thresholded peaks files {ENCFF533NSU|/files/ENCFF533NSU/} processed by ChIP-seq ENCODE4 v1.5.1 GRCh38 pipeline have a rescue ratio of 1.34 and a self consistency ratio of 2.86. According to ENCODE standards, having both rescue ratio and self consistency ratio values < 2 is recommended, but having only one of the ratio values < 2 is acceptable.' labels: reference_genome: hg38/genomes/GRCh38-hg38 accession: ENCSR076SHT status: released assay_term_name: ChIP-seq simple_biosample_summary: genetically modified (insertion) using CRISPR targeting H. sapiens GPN1 biosample_summary: Homo sapiens HepG2 genetically modified (insertion) using CRISPR targeting H. sapiens GPN1 replication_type: isogenic biosample_ontology: /biosample-types/cell_line_EFO_0001187/ perturbed: false doi: 10.17989/ENCSR076SHT date_created: '2018-11-26T17:50:03.383028+00:00' date_released: '2020-08-28' submitter_comment: '' target: GPN1