type: position_score table: filename: ENCFF351YOQ.tabix.bed.gz header_mode: none zero_based: true format: tabix chrom: column_index: 0 pos_begin: column_index: 1 pos_end: column_index: 2 scores: - id: TF_ChIP-seq_ENCSR000ALJ column_index: 3 type: float desc: signal histogram: type: number number_of_bins: 100 meta: summary: 'ChIP-seq ENCSR000ALJ [TISSUE: Homo sapiens keratinocyte female, TARGET: CTCF]' description: '**status**: released **biological\_replicates**: Rep 1, Rep 2, Rep 3 **summary**: female **output\_type**: conservative IDR thresholded peaks **audit\_error**: Processed alignments file {ENCFF012QCG|/files/ENCFF012QCG/} processed by ChIP-seq ENCODE4 v1.5.1 GRCh38 pipeline has 4824171 usable fragments. The minimum ENCODE standard for each replicate in a ChIP-seq experiment targeting CTCF-human and investigated as a transcription factor is 10 million usable fragments. The recommended value is > 20 million, but > 10 million is acceptable. (See {ENCODE ChIP-seq data standards|/data-standards/chip-seq/} ) **audit\_error**: Processed alignments file {ENCFF035SXH|/files/ENCFF035SXH/} processed by ChIP-seq ENCODE4 v1.5.1 GRCh38 pipeline has 3833119 usable fragments. The minimum ENCODE standard for each replicate in a ChIP-seq experiment targeting CTCF-human and investigated as a transcription factor is 10 million usable fragments. The recommended value is > 20 million, but > 10 million is acceptable. (See {ENCODE ChIP-seq data standards|/data-standards/chip-seq/} ) **audit\_error**: Processed alignments file {ENCFF756YJE|/files/ENCFF756YJE/} processed by ChIP-seq ENCODE4 v1.5.1 GRCh38 pipeline has 2529297 usable fragments. The minimum ENCODE standard for each replicate in a ChIP-seq experiment targeting CTCF-human and investigated as a transcription factor is 10 million usable fragments. The recommended value is > 20 million, but > 10 million is acceptable. (See {ENCODE ChIP-seq data standards|/data-standards/chip-seq/} ) **audit\_internal\_action**: Released analysis {ENCAN431RTN|/analyses/ENCAN431RTN/} has in progress subobject document {ff88aa16-be9d-480c-9bdd-745949c896db|/documents/ff88aa16-be9d-480c-9bdd-745949c896db/} **audit\_internal\_action**: Released analysis {ENCAN431RTN|/analyses/ENCAN431RTN/} has in progress subobject quality standard {encode4-tf-chip|/quality-standards/encode4-tf-chip/} **audit\_warning**: PBC1 (PCR Bottlenecking Coefficient 1, M1/M\_distinct) is the ratio of the number of genomic locations where exactly one read maps uniquely (M1) to the number of genomic locations where some reads map (M\_distinct). A PBC1 value in the range 0 - 0.5 is severe bottlenecking, 0.5 - 0.8 is moderate bottlenecking, 0.8 - 0.9 is mild bottlenecking, and > 0.9 is no bottlenecking. PBC1 value > 0.9 is recommended, but > 0.8 is acceptable. ENCODE processed alignments file {ENCFF012QCG|/files/ENCFF012QCG/} processed by ChIP-seq ENCODE4 v1.5.1 GRCh38 pipeline was generated from a library with PBC1 value of 0.89. **audit\_warning**: PBC2 (PCR Bottlenecking Coefficient 2, M1/M2) is the ratio of the number of genomic locations where exactly one read maps uniquely (M1) to the number of genomic locations where two reads map uniquely (M2). A PBC2 value in the range 0 - 1 is severe bottlenecking, 1 - 3 is moderate bottlenecking, 3 - 10 is mild bottlenecking, > 10 is no bottlenecking. PBC2 value > 10 is recommended, but > 3 is acceptable. ENCODE processed alignments file {ENCFF012QCG|/files/ENCFF012QCG/} processed by ChIP-seq ENCODE4 v1.5.1 GRCh38 pipeline was generated from a library with PBC2 value of 9.45. **audit\_warning**: PBC1 (PCR Bottlenecking Coefficient 1, M1/M\_distinct) is the ratio of the number of genomic locations where exactly one read maps uniquely (M1) to the number of genomic locations where some reads map (M\_distinct). A PBC1 value in the range 0 - 0.5 is severe bottlenecking, 0.5 - 0.8 is moderate bottlenecking, 0.8 - 0.9 is mild bottlenecking, and > 0.9 is no bottlenecking. PBC1 value > 0.9 is recommended, but > 0.8 is acceptable. ENCODE processed alignments file {ENCFF756YJE|/files/ENCFF756YJE/} processed by ChIP-seq ENCODE4 v1.5.1 GRCh38 pipeline was generated from a library with PBC1 value of 0.89. **audit\_warning**: PBC2 (PCR Bottlenecking Coefficient 2, M1/M2) is the ratio of the number of genomic locations where exactly one read maps uniquely (M1) to the number of genomic locations where two reads map uniquely (M2). A PBC2 value in the range 0 - 1 is severe bottlenecking, 1 - 3 is moderate bottlenecking, 3 - 10 is mild bottlenecking, > 10 is no bottlenecking. PBC2 value > 10 is recommended, but > 3 is acceptable. ENCODE processed alignments file {ENCFF756YJE|/files/ENCFF756YJE/} processed by ChIP-seq ENCODE4 v1.5.1 GRCh38 pipeline was generated from a library with PBC2 value of 8.69.' labels: reference_genome: hg38/genomes/GRCh38-hg38 accession: ENCSR000ALJ status: released assay_term_name: ChIP-seq simple_biosample_summary: female biosample_summary: Homo sapiens keratinocyte female replication_type: isogenic biosample_ontology: /biosample-types/primary_cell_CL_0000312/ perturbed: false doi: 10.17989/ENCSR000ALJ date_created: '2013-11-07T22:16:07.231430+00:00' date_released: '2011-02-10' submitter_comment: '' target: CTCF